Equipment name & NEMO ID Training Required & Charges Cleanliness Location Notes
EVG Wafer Bonder
evbond
Wafer Bonder EVG Training Flexible SNF Cleanroom Paul G Allen L107
Fiji 2 ALD
fiji2
ALD Fiji 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107
Heidelberg MLA 150
heidelberg
Heidelberg Training All SNF Exfab Paul G Allen 104 Stinson

Direct Write

Heidelberg MLA 150 - 2
heidelberg2
Heidelberg Training All SNF Cleanroom Paul G Allen L107

Direct Write

micromanipulator6000 IV-CV probe station
micromanipulator6000
micromanipulator6000 IV-CV probe station Training All SNF Exfab Paul G Allen 151 Ocean
PDS 2010 LABCOTER™ 2 Parylene Deposition System
parcoater
Parylene Coater Training Flexible SNF Exfab Paul G Allen 155 Mavericks
PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Profilometer AlphaStep D-300
alphastep2
AlphaStep2 Training Flexible SNF Exfab Paul G Allen 104 Stinson
Samco PC300 Plasma Etch System
samco
Samco Training Flexible SNF Cleanroom Paul G Allen L107
Savannah ALD
savannah
ALD Savannah Training Flexible SNF Cleanroom Paul G Allen L107
SEM -Zeiss Merlin
sem-merlin
SEM-Merlin Training All SNF Exfab Paul G Allen 104 Stinson
Woollam
woollam
Woollam Training All SNF Cleanroom Paul G Allen L107
Equipment name & NEMO ID Technique Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Minimum Resolution Exposure Wavelength Process Temperature Range Gases Sample Size Limits Substrate Size Substrate Type Maximum Load
EVG Wafer Bonder
evbond
Flexible ,
,
,
,
,
Fiji 2 ALD
fiji2
Flexible
1.00 Å - 50.00 nm
24 °C - 350 °C
,
,
,
,
,
,
,
,
,
,
,
,
Heidelberg MLA 150
heidelberg
All
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
PDS 2010 LABCOTER™ 2 Parylene Deposition System
parcoater
Flexible ,
,
,
,
,
,
,
,
,
,
,
,
PlasmaTherm Shuttlelock PECVD System
ccp-dep
All
100.00 Å - 4.00 μm
100 °C - 350 °C
,
,
,
,
,
,
,
,
4
Profilometer AlphaStep D-300
alphastep2
Flexible ,
,
,
,
,
,
,
,
,
,
,
,
1
Samco PC300 Plasma Etch System
samco
Flexible
20 ºC
,
,
,
,
,
,
,
,
,
,
,
,
,
Four 4" wafers or two 6" wafers and one 8" wafer
Savannah ALD
savannah
Flexible
1.00 Å - 50.00 nm
24 °C - 250 °C
,
,
,
,
,
,
,
,
,
,
,
,
SEM -Zeiss Merlin
sem-merlin
All
0.00 mm - 35.00 mm
6 in wafer ,
,
,
,
,
,
,
,
,
,
Woollam
woollam
All ,
,
,
,
,
,
,
,
,
,
,
,
,
1