The following is a list of equipment where 4 inch round substrates are allowed.

Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort ascending Notes
Oven 90°C prebake
oven90
Resist Prebake Oven 90°C Training All SNF Cleanroom Paul G Allen L107

Bakes wafers after resist coating.

Prometrix Resistivity Mapping System
prometrix
Prometrix Training All SNF Cleanroom Paul G Allen L107

3 Probe Heads for different cleanliness groups.

Samco PC300 Plasma Etch System
samco
Samco Training Flexible SNF Cleanroom Paul G Allen L107
Fiji 3 ALD
fiji3
ALD Fiji 3 Training Flexible SNF Cleanroom Paul G Allen L107

Restricted to non-conductive films only

Wet Bench Miscellaneous
wbmiscres
Wet Bench Miscellaneous Photoresist Training Flexible SNF Cleanroom Paul G Allen L107

Manual development of resist in beakers and Headway (manual resist spinner). SNF approved developers (acid or base). No solvents!

Matrix Plasma Resist Strip
matrix
Matrix Plasma Resist Strip Training Flexible SNF Cleanroom Paul G Allen L107

Single wafer tool with auto loading from a cassette. Pieces need a pocket carrier wafer for transport. Chuck temperature controls wafer heating.

Karl Suss MA-6 Contact Aligner
karlsuss2
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align.

Flexus 2320 Stress Tester
stresstest
Stress Tester Flexus 2320 Training All SNF Cleanroom Paul G Allen L107
Lesker2 Sputter
lesker2-sputter
Sputter Lesker 1&2 Training Semiclean SNF Cleanroom Paul G Allen L107

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

MVD
mvd
MVD Training Flexible SNF Cleanroom Paul G Allen L107

Reactor located inside glovebox

Wet Bench Resist Strip
wbresstrip-1
Wet Bench Resist Strip Clean (Ge), Semiclean, Flexible SNF Cleanroom Paul G Allen L107

Wet Resist Removal: SRS-100 or PRS1000

Xactix Xenon Difluoride Etcher
xactix
Xactix Xenon Difluoride Etcher Training All SNF Cleanroom Paul G Allen L107

Isotropic Si etching; can be used for backside Si removal on small pieces

Karl Suss MA-6 Contact Aligner
karlsuss
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align, including IR.

AJA2 Evaporator
aja2-evap
Evaporator AJA2 Semiclean SNF Cleanroom Paul G Allen L107

For more than 300nm deposition, please contact Graham Ewing<grahamj.ewing@stanford.edu> in advance

Savannah ALD
savannah
ALD Savannah Training Flexible SNF Cleanroom Paul G Allen L107
Wet Bench Clean_res-hf
wbclean_res-hf
Wet Bench Clean Piranha/HF/Phosphoric Training Clean SNF Cleanroom Paul G Allen L107

Resist as mask allowed

Plasma Therm Versaline LL ICP Deep Silicon Etcher
PT-DSE
Plasma Therm Versaline LL ICP Deep Silicon Etcher Training Flexible SNF Cleanroom Paul G Allen L107

Single wafer; Bosch process for Si etching; Default 4" config; Can be converted to 6" config; pieces need to be attached to carrier wafer; need a support wafer for through wafer etching, can be used for Isotropic Si Etching

ASML PAS 5500/60 i-line Stepper
asml
Stepper ASML PAS 5500/60 i-line Training All SNF Cleanroom Paul G Allen L107

5:1 reducing stepper

Intlvac Evaporator
Intlvac_evap
Evaporator Intlvac Training Clean, Semiclean SNF Cleanroom Paul G Allen L107
Woollam
woollam
Woollam Training All SNF Cleanroom Paul G Allen L107

Pages

Equipment name & NEMO ID Technique Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
Gasonics Aura Asher
gasonics
Clean, Semiclean
25
Headway 3 Manual Resist Spinner
headway3
All 1 piece or wafer
Headway Manual Resist Spinner
headway2
All ,
,
,
,
,
,
,
,
,
one piece or wafer
Heidelberg MLA 150
heidelberg
All
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
All
150 ºC
,
,
,
,
,
,
,
,
Intlvac Evaporator
Intlvac_evap
Clean, Semiclean
0.00 - 0.50 μm
,
,
12 4 inch wafers, 2 6 inch wafers
Karl Suss MA-6 Contact Aligner
karlsuss
All
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lam Research TCP 9400 Poly Etcher
lampoly
Clean, Semiclean
,
25
Laurell Manual Resist Spinner
laurell-R
All
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
All 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
Matrix Plasma Resist Strip
matrix
Flexible
,
,
,
,
25
micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
MRC Reactive Ion Etcher
mrc
Flexible 1
MVD
mvd
Flexible
1.00 Å - 50.00 nm
24 °C - 150 °C
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,