Skip to content Skip to navigation

4 inch wafer

Short Name: 
4"

The following is a list of equipment where 4 inch round substrates are allowed.

Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort descending Notes
Laurell Manual Resist Spinner
laurell-R
Laurell Manual Resist Spinner Training All SNF Cleanroom Paul G Allen L107

SU-8, LOL, Ebeam resists allowed. No Acetone allowed. 

RTA AllWin 610
aw610_r
AllWin 610 RTA Training Flexible SNF Cleanroom Paul G Allen L107
Tystar Bank 3 Tube 9
B3T9 Clean Oxide
Tystar Atmospheric Tube Training Clean SNF Cleanroom Paul G Allen L107
Wet Bench Clean_res-piranha
wbclean_res-piranha
Wet Bench Clean Piranha/HF/Phosphoric Training Clean SNF Cleanroom Paul G Allen L107

Resist will be removed

EVG 101 Spray Coater
evgspraycoat
Spray Coater EVG 101 Training All SNF Cleanroom Paul G Allen L107

Spray coating of resists

RTA AllWin 610
aw610_l
AllWin 610 RTA Training Clean SNF Cleanroom Paul G Allen L107
Tystar Bank 1 Tube 1
B1T1 Flexible Oxide
Tystar Atmospheric Tube Training Flexible SNF Cleanroom Paul G Allen L107
AMAT Centurion Epitaxial System
epi2
Epitaxial AMAT Centurion Training Clean SNF Cleanroom Paul G Allen L107

N and P doping available- intrinsic to 5E19 Operating pressure range is 5-300Torr

Wet Bench Flexcorr 3
wbflexcorr-3
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials using acids or bases. Hot Plate available. GaAs not allowed.

SVG Resist Coat Track 1
svgcoat
SVG Resist Coat Tracks 1 and 2 Training All SNF Cleanroom Paul G Allen L107

Automatic Resist spinning and bake

PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Wet Bench Flexible Solvents
wbflexsolv
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning of substrates or resist removal.

SPTS uetch vapor etch
uetch
SPTS uetch vapor etch Training All SNF Cleanroom Paul G Allen L107

Pieces need a carrier wafer; Isotropic Etching

EVG Wafer Bonder
evbond
Wafer Bonder EVG Training Flexible SNF Cleanroom Paul G Allen L107
PlasmaTherm Versaline HDP CVD System
hdpcvd
PlasmaTherm Versaline HDP CVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level there are cleans required for both the chamber and wafers prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) .  Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Critical Point Dryer Tousimis Automegasamdri-915B
cpd
Critical Point Dryer Training Flexible SNF Cleanroom Paul G Allen L107

CO2 drying after release of micromachined devices

HMDS Vapor Prime Oven, YES
yes
YES Prime Oven Training All SNF Cleanroom Paul G Allen L107

Two programs: Singe and HMDS prime or Singe only. No Resist allowed!

Wet Bench Clean_res- hotphos
wbclean_res-hotphos
Wet Bench Clean Piranha/HF/Phosphoric Training Clean SNF Cleanroom Paul G Allen L107

Resist should have been removed

Wet Bench Clean 1
wbclean-1
Wet Bench Clean1and2 Training Clean SNF Cleanroom Paul G Allen L107

No resist allowed. Resist should have been removed at the wbclean_res-piranha.

Oven (White)
white-oven
White Oven Training Flexible SNF Cleanroom Paul G Allen L107

For LOL2000 bake or bakes which are not allowed in the other ovens and need higher temperatures, up to 200C, programmable.

Pages

Equipment name & NEMO ID Technique Cleaning Required Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Resist Developer Process Temperature Range Gases Sample Size Limits Substrate Size Substrate Type Maximum Load
Samco PC300 Plasma Etch System
samco
Flexible
20 ºC
,
,
,
,
,
,
,
,
,
,
,
,
,
Four 4" wafers or two 6" wafers and one 8" wafer
Savannah ALD
savannah
Flexible
1.00 Å - 50.00 nm
24 °C - 250 °C
,
,
,
,
,
,
,
,
,
,
,
,
SEM -Zeiss Merlin
sem-merlin
All
0.00 mm - 35.00 mm
6 in wafer ,
,
,
,
,
,
,
,
,
,
Sensofar S-neox
s-neox
All ,
,
,
,
,
,
,
,
1
Sinton Lifetime Tester
sinton-lifetime-tester
Flexible
SPTS uetch vapor etch
uetch
All ,
,
,
,
,
,
,
,
,
1
SVG Develop Track 1
svgdev
All
,
,
,
,
,
,
,
,
25 4 inch wafers
SVG Develop Track 2
svgdev2
All
,
,
,
,
,
,
,
,
25 4 inch wafers
SVG Resist Coat Track 1
svgcoat
All
,
,
,
,
,
,
,
,
25 4 inch wafers
SVG Resist Coat Track 2
svgcoat2
All
,
,
,
,
,
,
,
,
25 4 inch wafers
Technics Asher
technics
Flexible
,
,
Four 4" wafers to pieces, one 6" or 8" wafer
Tencor P2 Profilometer
p2
Clean, Semiclean ,
,
,
,
,
,
,
,
1
Thermco3 Oxidation Furnace
thermco 3
Pre-Diffusion Clean Clean
25.00 Å - 2.00 μm
700 °C - 1100 °C
50
Tylan9 Forming Gas Anneal Furnace
tylan9
Flexible
250 °C - 1100 °C
,
,
50
Tylanfga Forming Gas Anneal Furnace
tylanfga
Standard Metal Clean Semiclean
100.00 Å - 100.00 Å
250 °C - 800 °C
50
Tystar Bank 1 Tube 1
B1T1 Flexible Oxide
Flexible
25.00 Å - 2.00 μm
400 °C - 1100 °C
,
,
100
Tystar Bank 1 Tube 2
B1T2 Flexible Oxide Anneal
Flexible
25.00 Å - 2.00 μm
400 °C - 1100 °C
,
,
100
Tystar Bank 2 Tube 5
B2T5 Clean Oxide Anneal
Pre-Diffusion Clean Clean
25.00 Å - 2.00 μm
400 °C - 1100 °C
,
,
100
Tystar Bank 2 Tube 6
B2T6 Clean Oxide
Pre-Diffusion Clean Clean
25.00 Å - 2.00 μm
400 °C - 1100 °C
,
,
100
Tystar Bank 3 Tube 9
B3T9 Clean Oxide
Pre-Diffusion Clean Clean
25.00 Å - 2.00 μm
400 °C - 1100 °C
,
,
100

Pages