Skip to content Skip to navigation

Pieces

Short Name: 
Pieces
Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort descending Notes
RTA AllWin 610
aw610_r
AllWin 610 RTA Training Flexible SNF Cleanroom Paul G Allen L107
Fiji 1 ALD
fiji1
ALD Fiji 1 and 2 Training Semiclean SNF Cleanroom Paul G Allen L107
Xactix Xenon Difluoride Etcher
xactix
Xactix Xenon Difluoride Etcher Training All SNF Cleanroom Paul G Allen L107

Isotropic Si etching; can be used for backside Si removal on small pieces

RTA AllWin 610
aw610_l
AllWin 610 RTA Training Clean SNF Cleanroom Paul G Allen L107
Laurell Manual Resist Spinner
laurell-R
Laurell Manual Resist Spinner Training All SNF Cleanroom Paul G Allen L107

SU-8, LOL, Ebeam resists allowed. No Acetone allowed. 

Heidelberg MLA 150 - 2
heidelberg2
Heidelberg Training All SNF Cleanroom Paul G Allen L107

Direct Write

PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

EVG 101 Spray Coater
evgspraycoat
Spray Coater EVG 101 Training All SNF Cleanroom Paul G Allen L107

Spray coating of resists

EVG Wafer Bonder
evbond
Wafer Bonder EVG Training Flexible SNF Cleanroom Paul G Allen L107
Technics Asher
technics
Technics Asher Training Flexible SNF Cleanroom Paul G Allen L107
PlasmaTherm Versaline HDP CVD System
hdpcvd
PlasmaTherm Versaline HDP CVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level there are cleans required for both the chamber and wafers prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) .  Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

SPTS uetch vapor etch
uetch
SPTS uetch vapor etch Training All SNF Cleanroom Paul G Allen L107

Pieces need a carrier wafer; Isotropic Etching

Wet Bench Flexcorr 1
wbflexcorr-1
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials. Hot plate available. GaAs allowed in personal labware only.

HMDS Vapor Prime Oven, YES
yes
YES Prime Oven Training All SNF Cleanroom Paul G Allen L107

Two programs: Singe and HMDS prime or Singe only. No Resist allowed!

Sensofar S-neox
s-neox
Sensofar S-neox Training All SNF Cleanroom Paul G Allen L107

non contact 3D optical profiling

Samco PC300 Plasma Etch System
samco
Samco Training Flexible SNF Cleanroom Paul G Allen L107
Wet Bench Flexcorr 2
wbflexcorr-2
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials. Hot pots available. GaAs allowed in personal labware only

Oven (White)
white-oven
White Oven Training Flexible SNF Cleanroom Paul G Allen L107

For LOL2000 bake or bakes which are not allowed in the other ovens and need higher temperatures, up to 200C, programmable.

Tencor P2 Profilometer
p2
Tencor P2 Profilometer Training Clean, Semiclean SNF Cleanroom Paul G Allen L107

Step height measurement range 500 Å to 80 µm

Lesker2 Sputter
lesker2-sputter
Sputter Lesker 1&2 Training Semiclean SNF Cleanroom Paul G Allen L107

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

Pages

Equipment name & NEMO ID Technique Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Accessories Available Resolution Notes Substrate Size Substrate Type Maximum Load
Heidelberg MLA 150
heidelberg
All
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
All
150 ºC
,
,
,
,
,
,
,
,
Intlvac Evaporator
Intlvac_evap
Clean, Semiclean
0.00 - 0.50 μm
,
,
12 4 inch wafers, 2 6 inch wafers
Karl Suss MA-6 Contact Aligner
karlsuss
All
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lakeshore Hall Measurement System
LakeshoreHall
All
100.00 μm - 1000.00 μm
-258 °C - 1000 °C
8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
1 piece
Laurell Manual Resist Spinner
laurell-R
All
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
Malvern Dynamic Light Scattering (DLS) Zetasizer
malvern-dls
Flexible

Integrating Sphere

micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
MRC Reactive Ion Etcher
mrc
Flexible 1
MVD
mvd
Flexible
1.00 Å - 50.00 nm
24 °C - 150 °C
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,
Nanospec 3
nanospec3
All
Optomec Printer
optomec-printer
Flexible
Oven (White)
white-oven
Flexible
0 °C - 200 °C
,
,
,
,
,
,
,
,
Oven 110°C post-bake
oven110
All
110 ºC
,
,
,
,
,
,
,
,
,

Pages