Skip to content Skip to navigation

Pieces

Short Name: 
Pieces
Subscribe to
Equipment name & NEMO ID Training Required & Chargessort ascending Cleanliness Location Notes
Xactix Xenon Difluoride Etcher
xactix
Xactix Xenon Difluoride Etcher Training All SNF Cleanroom Paul G Allen L107

Isotropic Si etching; can be used for backside Si removal on small pieces

Wet Bench Resist Strip
wbresstrip-1
Wet Bench Resist Strip Clean (Ge), Semiclean, Flexible SNF Cleanroom Paul G Allen L107

Wet Resist Removal: SRS-100 or PRS1000

Wet Bench Miscellaneous
wbmiscres
Wet Bench Miscellaneous Photoresist Training Flexible SNF Cleanroom Paul G Allen L107

Manual development of resist in beakers and Headway (manual resist spinner). SNF approved developers (acid or base). No solvents!

Wet Bench Flexible Solvents 2
wbflexsolv-2
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning, hot plate

Wet Bench Flexible Solvents 1
wbflexsolv-1
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning, two ultrasonic baths.

Wet Bench Flexible Solvents
wbflexsolv
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning of substrates or resist removal.

Wet Bench Flexcorr 2
wbflexcorr-2
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials. Hot pots available. GaAs allowed in personal labware only

Wet Bench Flexcorr 4
wbflexcorr-4
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials using acids or bases. Hot plate, HF bath, and controlled temperature bath available. GaAs not allowed.

Wet Bench Flexcorr 3
wbflexcorr-3
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials using acids or bases. Hot Plate available. GaAs not allowed.

Wet Bench Flexcorr 1
wbflexcorr-1
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials. Hot plate available. GaAs allowed in personal labware only.

Ex Fab Solvent Wet Bench
wbexfab_solv
WbExfab_Solv Training Flexible SNF Exfab Paul G Allen 104 Stinson
Ex Fab Develop Wet Bench
wbexfab_dev
WbExfab_Dev Training Flexible SNF Exfab Paul G Allen 104 Stinson

Manual development of resist in beakers. SNF approved developers only. No solvents!

Thermco3 Oxidation Furnace
thermco 3
Thermco 3 Oxidation Furnaces Training Clean SNF Cleanroom Paul G Allen L107

Dry and wet oxidation. Use calculator to determine growth rate. N2 annealing available.

Tencor P2 Profilometer
p2
Tencor P2 Profilometer Training Clean, Semiclean SNF Cleanroom Paul G Allen L107

Step height measurement range 500 Å to 80 µm

SPTS uetch vapor etch
uetch
SPTS uetch vapor etch Training All SNF Cleanroom Paul G Allen L107

Pieces need a carrier wafer; Isotropic Etching

Sinton Lifetime Tester
sinton-lifetime-tester
Sinton Lifetime Tester Training Flexible SNF Exfab Paul G Allen 151 Ocean
PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Plasmaetch PE-50
plasma-etch
Plasmaetch PE-50 Training Flexible SNF Exfab Paul G Allen 155 Mavericks

Low power, high pressure plasma; low bias, minimal damage. Often used for surface treatment At SNF - nSiL lab

Optomec Printer
optomec-printer
Optomec Printer Training Flexible SNF Exfab Paul G Allen 155A Venice
Nanospec 210XP
nanospec2
Nanospec Training All SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

Pages

Equipment name & NEMO ID Technique Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Accessories Available Resolution Notes Substrate Size Substrate Type Maximum Load
Heidelberg MLA 150
heidelberg
All
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
All
150 ºC
,
,
,
,
,
,
,
,
Intlvac Evaporator
Intlvac_evap
Clean, Semiclean
0.00 - 0.50 μm
,
,
12 4 inch wafers, 2 6 inch wafers
Karl Suss MA-6 Contact Aligner
karlsuss
All
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lakeshore Hall Measurement System
LakeshoreHall
All
100.00 μm - 1000.00 μm
-258 °C - 1000 °C
8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
1 piece
Laurell Manual Resist Spinner
laurell-R
All
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
Malvern Dynamic Light Scattering (DLS) Zetasizer
malvern-dls
Flexible

Integrating Sphere

micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
MRC Reactive Ion Etcher
mrc
Flexible 1
MVD
mvd
Flexible
1.00 Å - 50.00 nm
24 °C - 150 °C
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,
Nanospec 3
nanospec3
All
Optomec Printer
optomec-printer
Flexible
Oven (White)
white-oven
Flexible
0 °C - 200 °C
,
,
,
,
,
,
,
,
Oven 110°C post-bake
oven110
All
110 ºC
,
,
,
,
,
,
,
,
,

Pages