Skip to content Skip to navigation

Quartz

Chemical Formula: 
SiO2
Subscribe to
Equipment name & NEMO ID Training Required & Chargessort descending Cleanliness Location Notes
Woollam
woollam
Woollam Training All SNF Cleanroom Paul G Allen L107
Karl Suss MA-6 Contact Aligner
karlsuss
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align, including IR.

Karl Suss MA-6 Contact Aligner
karlsuss2
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align.

Wet Bench Solvent Lithography
lithosolv
Lithography Solvent Bench Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning of substrates or masks. Teflon coated metal tweezers cleaning.

Matrix Plasma Resist Strip
matrix
Matrix Plasma Resist Strip Training Flexible SNF Cleanroom Paul G Allen L107

Single wafer tool with auto loading from a cassette. Pieces need a pocket carrier wafer for transport. Chuck temperature controls wafer heating.

micromanipulator6000 IV-CV probe station
micromanipulator6000
micromanipulator6000 IV-CV probe station Training All SNF Exfab Paul G Allen 151 Ocean
Nanospec 210XP
nanospec2
Nanospec Training All SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

Oxford Dielectric Etcher
oxford-rie
Oxford Dielectric Etcher Training Flexible SNF Cleanroom Paul G Allen L107

4" wafers; can be adopted to do 6" or 8" wafers; pieces need to be bonded to carrier wafers

PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Prometrix Resistivity Mapping System
prometrix
Prometrix Training All SNF Cleanroom Paul G Allen L107

3 Probe Heads for different cleanliness groups.

SPTS uetch vapor etch
uetch
SPTS uetch vapor etch Training All SNF Cleanroom Paul G Allen L107

Pieces need a carrier wafer; Isotropic Etching

SVG Resist Coat Track 2
svgcoat2
SVG Resist Coat Tracks 1 and 2 Training All SNF Cleanroom Paul G Allen L107

Automatic HMDS, Resist spinning, and Bake. AZ5214IR Image Reversal.

SVG Resist Coat Track 1
svgcoat
SVG Resist Coat Tracks 1 and 2 Training All SNF Cleanroom Paul G Allen L107

Automatic Resist spinning and bake

SVG Develop Track 1
svgdev
SVG Resist Develop tracks 1 and 2 Training All SNF Cleanroom Paul G Allen L107

Automatic development.

SVG Develop Track 2
svgdev2
SVG Resist Develop tracks 1 and 2 Training All SNF Cleanroom Paul G Allen L107

Automatic development.

Tencor P2 Profilometer
p2
Tencor P2 Profilometer Training Clean, Semiclean SNF Cleanroom Paul G Allen L107

Step height measurement range 500 Å to 80 µm

Wet Bench Clean_res- hotphos
wbclean_res-hotphos
Wet Bench Clean Piranha/HF/Phosphoric Training Clean SNF Cleanroom Paul G Allen L107

Resist should have been removed

Wet Bench Clean_res-piranha
wbclean_res-piranha
Wet Bench Clean Piranha/HF/Phosphoric Training Clean SNF Cleanroom Paul G Allen L107

Resist will be removed

Wet Bench Clean_res-hf
wbclean_res-hf
Wet Bench Clean Piranha/HF/Phosphoric Training Clean SNF Cleanroom Paul G Allen L107

Resist as mask allowed

Wet Bench CMOS Metal
wbclean3
Wet Bench CMOS Metal (wbclean3) Training Semiclean SNF Cleanroom Paul G Allen L107

Al, Ti, or W wet etching or oxide etching

Pages

Equipment name & NEMO ID Technique Cleaning Required Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Process Temperature Range Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lakeshore Hall Measurement System
LakeshoreHall
All
100.00 μm - 1000.00 μm
-258 °C - 1000 °C
8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
1 piece
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
All 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
Matrix Plasma Resist Strip
matrix
Flexible
,
,
,
,
25
micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,
Oven (White)
white-oven
Flexible
0 °C - 200 °C
,
,
,
,
,
,
,
,
Oven 110°C post-bake
oven110
All
110 ºC
,
,
,
,
,
,
,
,
,
Oven 90°C prebake
oven90
All
90 ºC
,
,
,
,
,
,
,
,
Oven BlueM 200°C to 430°C
bluem
Flexible
0 °C - 430 °C
,
,
,
,
,
,
,
,
,
Oxford Dielectric Etcher
oxford-rie
Flexible
,
,
,
,
1
PDS 2010 LABCOTER™ 2 Parylene Deposition System
parcoater
Flexible ,
,
,
,
,
,
,
,
,
,
,
,
PlasmaTherm Shuttlelock PECVD System
ccp-dep
All
100.00 Å - 4.00 μm
100 °C - 350 °C
,
,
,
,
,
,
,
,
4
Profilometer Alphastep 500
alphastep
Flexible ,
,
,
,
,
,
,
,
1
Profilometer AlphaStep D-300
alphastep2
Flexible ,
,
,
,
,
,
,
,
,
,
,
,
1
Prometrix Resistivity Mapping System
prometrix
All ,
,
,
,
,
,
,
,
1
RTA AllWin 610
aw610_l
Pre-Diffusion Clean Clean
21 °C - 1150 °C
,
,
1 wafer

Pages