Skip to content Skip to navigation

Germanium

Chemical Formula: 
Ge
Subscribe to
Equipment name & NEMO ID Training Required & Chargessort descending Cleanliness Location Notes
Fiji 2 ALD
fiji2
ALD Fiji 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107
Savannah ALD
savannah
ALD Savannah Training Flexible SNF Cleanroom Paul G Allen L107
AJA2 Evaporator
aja2-evap
Evaporator AJA2 Semiclean SNF Cleanroom Paul G Allen L107

For more than 300nm deposition, please contact Graham Ewing<grahamj.ewing@stanford.edu> in advance

Oven 90°C prebake
oven90
Resist Prebake Oven 90°C Training All SNF Cleanroom Paul G Allen L107

Bakes wafers after resist coating.

Oven 110°C post-bake
oven110
Resist Postbake Oven 110°C Training All SNF Cleanroom Paul G Allen L107

Bakes wafers with resist after the development, called post-bake.

Profilometer Alphastep 500
alphastep
Alphastep 500 Profilometer Training Flexible SNF Exfab Paul G Allen 104 Stinson

500Å to 300µm

Oven BlueM 200°C to 430°C
bluem
Blue M Oven Training Flexible SNF Cleanroom Paul G Allen L107

Convection in N2. Cure. Programmable.

Critical Point Dryer Tousimis Automegasamdri-915B
cpd
Critical Point Dryer Training Flexible SNF Cleanroom Paul G Allen L107

CO2 drying after release of micromachined devices

DISCO Wafer Saw
DISCO wafersaw
Wafersaw DISCO training Flexible SNF Exfab Paul G Allen 159 Capitola
Finetech Lambda
flipchipbonder
Flip Chip Bonder Training Flexible SNF Exfab Paul G Allen 104 Stinson
Headway Manual Resist Spinner
headway2
Resist Coat (manual) Headway Manual Training All SNF Cleanroom Paul G Allen L107

Adjustable spin speeds, spin time. SNF-acceptable resists or polymers. Ebeam resists

Woollam
woollam
Woollam Training All SNF Cleanroom Paul G Allen L107
Karl Suss MA-6 Contact Aligner
karlsuss
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align, including IR.

Karl Suss MA-6 Contact Aligner
karlsuss2
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align.

Wet Bench Solvent Lithography
lithosolv
Lithography Solvent Bench Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning of substrates or masks. Teflon coated metal tweezers cleaning.

micromanipulator6000 IV-CV probe station
micromanipulator6000
micromanipulator6000 IV-CV probe station Training All SNF Exfab Paul G Allen 151 Ocean
Nanospec 210XP
nanospec2
Nanospec Training All SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Prometrix Resistivity Mapping System
prometrix
Prometrix Training All SNF Cleanroom Paul G Allen L107

3 Probe Heads for different cleanliness groups.

SPTS uetch vapor etch
uetch
SPTS uetch vapor etch Training All SNF Cleanroom Paul G Allen L107

Pieces need a carrier wafer; Isotropic Etching

Pages

Equipment name & NEMO ID Technique Cleanliness Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
AJA Evaporator
aja-evap
Flexible
0.00 - 300.00 nm
,
,
,
,
,
,
,
,
,
,
,
4"x3 or 6"x1 wafers or pieces
AJA2 Evaporator
aja2-evap
Semiclean
0.00 - 300.00 nm
,
,
,
,
,
4"x3 or 6"x1 wafers or pieces
Critical Point Dryer Tousimis Automegasamdri-915B
cpd
Flexible
,
,
,
,
,
,
,
,
,
DISCO Wafer Saw
DISCO wafersaw
Flexible ,
,
,
,
,
,
,
,
1x4", 1x6" or 1x8" wafer, or pieces
Fiji 2 ALD
fiji2
Flexible
1.00 Å - 50.00 nm
24 °C - 350 °C
,
,
,
,
,
,
,
,
,
,
,
,
Finetech Lambda
flipchipbonder
Flexible
°C - 400 °C
,
,
,
,
,
1
Flexus 2320 Stress Tester
stresstest
All ,
,
,
,
,
,
,
,
1
Headway Manual Resist Spinner
headway2
All ,
,
,
,
,
,
,
,
,
one piece or wafer
Heidelberg MLA 150
heidelberg
All
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
All
150 ºC
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss
All
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lakeshore Hall Measurement System
LakeshoreHall
All
100.00 μm - 1000.00 μm
-258 °C - 1000 °C
8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
1 piece
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
All 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,

Pages