Skip to content Skip to navigation

Gallium Arsenide

Chemical Formula: 
GaAs
Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort descending Notes
Keyence Digital Microscope VHX-6000
keyence
Microscope Keyence Training All SNF Exfab Paul G Allen 104 Stinson
SEM -Zeiss Merlin
sem-merlin
SEM-Merlin Training All SNF Exfab Paul G Allen 104 Stinson
Profilometer AlphaStep D-300
alphastep2
AlphaStep2 Training Flexible SNF Exfab Paul G Allen 104 Stinson
Nanospec 210XP
nanospec2
Nanospec Training All SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

Profilometer Alphastep 500
alphastep
Alphastep 500 Profilometer Training Flexible SNF Exfab Paul G Allen 104 Stinson

500Å to 300µm

Heidelberg MLA 150
heidelberg
Heidelberg Training All SNF Exfab Paul G Allen 104 Stinson

Direct Write

Oven 110°C post-bake
oven110
Resist Postbake Oven 110°C Training All SNF Cleanroom Paul G Allen L107

Bakes wafers with resist after the development, called post-bake.

Samco PC300 Plasma Etch System
samco
Samco Training Flexible SNF Cleanroom Paul G Allen L107
Wet Bench Flexcorr 1
wbflexcorr-1
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials. Hot plate available. GaAs allowed in personal labware only.

Oven 90°C prebake
oven90
Resist Prebake Oven 90°C Training All SNF Cleanroom Paul G Allen L107

Bakes wafers after resist coating.

Lesker2 Sputter
lesker2-sputter
Sputter Lesker 1&2 Training Semiclean SNF Cleanroom Paul G Allen L107

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

Wet Bench Flexcorr 2
wbflexcorr-2
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials. Hot pots available. GaAs allowed in personal labware only

Karl Suss MA-6 Contact Aligner
karlsuss2
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align.

Wet Bench Miscellaneous
wbmiscres
Wet Bench Miscellaneous Photoresist Training Flexible SNF Cleanroom Paul G Allen L107

Manual development of resist in beakers and Headway (manual resist spinner). SNF approved developers (acid or base). No solvents!

Karl Suss MA-6 Contact Aligner
karlsuss
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align, including IR.

Wet Bench Flexible Solvents 1
wbflexsolv-1
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning, two ultrasonic baths.

Wet Bench Flexible Solvents 2
wbflexsolv-2
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning, hot plate

Sensofar S-neox
s-neox
Sensofar S-neox Training All SNF Cleanroom Paul G Allen L107

non contact 3D optical profiling

Wet Bench Solvent Lithography
lithosolv
Lithography Solvent Bench Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning of substrates or masks. Teflon coated metal tweezers cleaning.

Tencor P2 Profilometer
p2
Tencor P2 Profilometer Training Clean, Semiclean SNF Cleanroom Paul G Allen L107

Step height measurement range 500 Å to 80 µm

Pages

Equipment name & NEMO ID Technique Cleaning Required Cleanliness Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
Aixtron MOCVD - III-V system
aix200
Pre-Diffusion Clean Flexible
0.00 - 5.00 μm
300 °C - 800 °C
,
,
,
4"x1 wafer or 2"x1 wafer or 4 pieces
AJA Evaporator
aja-evap
Flexible
0.00 - 300.00 nm
,
,
,
,
,
,
,
,
,
,
,
4"x3 or 6"x1 wafers or pieces
Critical Point Dryer Tousimis Automegasamdri-915B
cpd
Flexible
,
,
,
,
,
,
,
,
,
DISCO Wafer Saw
DISCO wafersaw
Flexible ,
,
,
,
,
,
,
,
1x4", 1x6" or 1x8" wafer, or pieces
Flexus 2320 Stress Tester
stresstest
All ,
,
,
,
,
,
,
,
1
Headway Manual Resist Spinner
headway2
All ,
,
,
,
,
,
,
,
,
one piece or wafer
Heidelberg MLA 150
heidelberg
All
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
All
150 ºC
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss
All
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lakeshore Hall Measurement System
LakeshoreHall
All
100.00 μm - 1000.00 μm
-258 °C - 1000 °C
8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
1 piece
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
All 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,
Oven (White)
white-oven
Flexible
0 °C - 200 °C
,
,
,
,
,
,
,
,
Oven 110°C post-bake
oven110
All
110 ºC
,
,
,
,
,
,
,
,
,

Pages